Compliance with AS/NZS 3760 Test and Tag in regards to electrical safety of portable appliances

Ensure you are meeting your health and safety obligations.

Electrical appliance testing assures that your workers are kept safe from harm and that your appliances are free from electrical faults.

In QLD all testing can be conducted by a Competent Person however the Competent Person must also hold a Registered Electrical Contractors’ Licence.

Our capabilities are comprehensive and unparalleled.

Reduce the impact of electrical shocks and electrocution and the risk of electrical fires.  Ensure ALL of your equipment is regularly tested and tagged.

Our qualified Master Electricians can ensure you meet your legal obligations.

QLD regulations specify requirements by Classes of Work.

Manufacturing Work

  • 12 monthly
  • Double and Single Insulated items must be protected by a fixed electrical safety switch
  • 6 monthly
  • Double and Single Insulated items must be protected by a fixed safety switch
  • 6 monthly Push Button test
  • 12 monthly Operating Time Test
  • Daily or before each use
  • Push Button test12 monthly Operating Time Test
  • Portable RCD’s are not to be used as a primary RCD in Manufacturing Work

Service Work

  • 12 monthly OR all circuits protected by a safety switch
  • 6 monthly Push Button test
  • 12 monthly Operating Time Test
  • 3 monthly or before each use Push Button test
  • 12 monthly Operating Time Test

Office Work

  • 5 yearly OR all circuits protected by a safety switch
  • 6 monthly Push Button test
  • 2 yearly Operating Time Test
  • 3 monthly or before each use Push Button test
  • 2 yearly Operating Time Test

Construction Work

  • At least 3 monthly by a Competent Person
  • Monthly Push Button test
  • 12 monthly Operating Time Test
  • Daily or before each use Push Button test
  • 3 monthly Operating Time Test

Rural Industry Work

  • 12 monthly OR all circuits protected by a safety switch
  • All plug in equipment to be visually examined before each use
  • 3 monthly Push Button test recommended
  • 3 monthly Push Button test recommended

Applicable Legislation